System programming can only be executed using the first slot on an analog extension of the interface (default extension 11) equipped with an analogextension (MF) or on a KS-type system telephone or in the first slot of an optiPoint-type system telephone.
Is OptiSet E standart KS-type system...
We are only planning to buy new one HiPath, so i want to know if we must buy some new OptiPoint phones or it is possible to use those OptiSet phones that we already have...
So i have 2 questions:
1)If Optiset E phones could be used as system phones on Hipath 1120 (in basic config w/o any additional cards installed)?
2)if programming could be performed by using this kind of phone?
Hi, we have Siemens OfficePoint 150E (with CBPC, STLS4, FMC8, IMOD,V24/2 cards installed). I couldn't figure what happened, but when i trying to make some external call there is the problem: recipient couldn't hear me (but i can hear him). Same problem when i answering on external call... It's...
Are you sure that only settings from PBX side is baud rate setting? May be i must configure wich ports on V24 is used for connection/enable this feature/e.t.c.?
I had checked pinout of my cable another one time, and it is exactly the same, that described in manual (wich has no difference at all...
OK, ofc my nullmodem cable is not original cable by Hicom/Siemens, but it is properly pinned and hooked as you described (V24 interface (DB25) on PBX directly to Com (DB9) interface of PC without any other adapters) ...
On PBX side i setted up only 22-13 (baud rate value to 9600)
It seems that...
Now having problem while trying to connect PBX from Manager software: when i running "Extras>>>Start wizard>>>Hipath 3000>>>V24(Com1)" i always getting error message "Communication system is Offline. Check the cable connection" ...
Settings is 9600/8/1/none from both sides;
Communication cable...
Had ordered Interalia "The Voice" V-22 from ebay. Now waiting delivery...
Could somebody answer me about the ports on CBPC card, by wich this announcement device will have connected?
As i understood, to use this device, i must have one of the ports (Analog a/b (T/R) subscriber lines) on slot 3 (lower right corner of attached pic) free?
In case of using EXM card, in addition i must buy some announcement device? But why i need that EXM card at all? What is the functionality...
Thank you, i'll check software version of system soon.
My system is DID capable, but i think that managing it remotely by connected PC (TeamView, Remote Desktop e.t.c.) is much easier.
Hi, we have Siemens OfficePoint 150E (with CBPC, STLS4, FMC8, IMOD,
V24/2 cards installed). The task is to provide the "Announcement Before Answering" service. Which is the best way to perform this?
By now i am planning to buy EXM (S30817- Q902 -B401) card, and connect throught it some...
Hi, we have Siemens OfficePoint 150E (with CBPC, STLS4, FMC8, IMOD,
V24/2 cards installed). As i understood, i could connect it to the PC, using RS232 interface on V24/2 board by NullModem DB25M/DB9F cable. The question is: what software i must use to program/manage this device? In manual...
Guys, i really need help!
Sometimes trunks working good few days, sometimes they became out of service several times per day... I had tried different ports on BRI card, had changed some line settings with no result.
Yes - this is Europe (Greece)...
My bad - i didn't mention that, when trunks became out of service, it is not possible to call outside, nor recive incoming calls ((
And only thing that helps - it is soft reboot.
So we have Avaya IP office 500 with BRI 8U / VRM32 /DS extension cards installed... Connection with outer world powered with two ISDN lines (they connected to the first and third port of BRI card), each line represent two external phone numbers (by MSN). All working good, but sometimes trunk (or...