Hello,
Trying to set up CDR for genesis call accounting. CDR is turned on when I prt CDR_DATA from load 21.
The CDR is turned off when I print any of the RDB's from LD 21.
Does anyone know the exact config I need to get this running?
Thanks
i just tried forwarding a number that is on the same PRI and it worked.
The branch has a bcm50 which functions as a SRG. All the lines home into the cs1000(where 5787 is located).
Here is the programming i have. It still rings twice and gets a fast busy. Does the 6410 need to be programmed into the system? Or does it just have to be active on the PRI
DES WENDT
TN 096 0 00 03 PHANTOM
TYPE 500
CDEN 4D
CUST 0
ERL 00000
WRLS NO
DN 6410 0 MARP
AST NO
IAPG 0...
figured it out .. the erl should be ERL 00000
im still get busy signal after 2 rings . but im going to confirm if that number is active on the PRI.
To confirm does the number still need to be programmed in the local sites BCM or elsewhere in the CS1000?
this is where i programmed it. seems to be a phantom ..
DES WENDT
TN 096 0 00 03 PHANTOM
TYPE 500
CDEN 4D
CUST 0
ERL 00006
WRLS NO
DN 6410 0 MARP
AST NO
IAPG 0
HUNT
TGAR 4
LDN NO
NCOS 4
SGRP 0
RNPG 0
XLST 0
SCI 0
SCPW
CLS CTD DTN FBD XFD WTA THFD FND HTD ONS...
Also if i wanted to go the phantom way (if the did's arent already coming into the system) I get this message during
FTR DCFW 4 DN.
SCH0355
Unable to match input field with stored mnemonics
what am i missing here. I am using my own DN to test
Here's what we are trying to achieve. We want customers to think the sales guy is local to their city.
We have 3 locations with one sales guy.
Customers call a local number 306-555-3201 for location A
Customers call a local number 204-555-3202 for location B
Customers call a local number...
Hello,
Looking for forward 3 lines to 1. The 3 lines are active did's but not programmed to a phone. The line 4 did is programmed to a phone.
I was thinking creating 3 phantom TN's and forward those to line 4.
Am I on the right track?
Below is a printout of everything that is relevant
REQ: prt
TYPE: dn
TYPE DNB
CUST 0
DN 5000
DATE
PAGE
DES
DN 5000
TYPE LDN
**********************************
>ld 21
PT1000
REQ: prt
TYPE: ldn
TYPE LDN_DATA
CUST 0
TYPE LDN_DATA
CUST 00
OPT XLDN
DLDN NO
LDN0 5000
LDN1...
i can change the ATDN to a non-existant dn . but when i call the main number xxx-xxx-5000 it still reaches the attendant console.
Do I need to change the LDN to a specific DN?
so I tried changing the ATDN to an existing DN and getting
SCH0730
our DN is a 1120 IP phone not an attendant analouge console if that makes a difference
i get the below when i print a dnb on 3000
DN 3000
TYPE ATT
TN 000 0 05 00 15 SEP 1995
(2250)
and this is when i print the above TN
TN 000 0 05 00 VIRTUAL
TYPE 2250
CDEN 8D
CTYP XDLC
CUST 0
ERL 0
SGRP 0
SETN 000 0 05 01
ANUM 01
IADN
ALPD NO
SSU 0000...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.