  1. Straces

    OSB BRANCH

    Hi, if you want to create bootable USB, use tool usbsticksetup (USB Stick Setup) which help you create bootable USB [smile]
  2. Straces

    SLC24 instead of SLMAE on HiPath 4000

    Hello, i have here additional SLC24 card for cordless, on HiPath is not used SLMAE analogue card, can i install SLC24 instead? How is the procedure unplug SLMAE - plug SLC24 - configure? Thank you.
  3. Straces

    OPTIPOINT 410/420 ECONOMY HFA

    Hi, i think it is still same, check this: Important: It is necessary that the phone hardware contains the INCA©-IP chip V1.4. http://wiki.unify.com/wiki/optiPoint_SIP_HW_compatibility
  4. Straces

    OptipooptiPoint 410 standard S - cannot be reset by keys

    Hello, i have configured SIP optiPoint 410 standard S (V7 R6.10.0), we made some network changes and phone device cannot get IP, how can i make factory reset on the phone? On HFA version it was possible by keys (i think 289) or enter admin menu (i think 103), but on SIP version i cannot do it...
  5. Straces

    OpenStage 40 SIP to HFA fails

    Ok it seems that problem with changing firmware between SIP and HFA was solved by new Firmware.. SIP V3 R3.32.0 -> HFA V3 R0.28.0 working HFA V3 R0.28.0 -> HFA V3 R0.23.0 working HFA V3 R0.28.0 -> SIP V3 R3.32.0 working SIP V3 R3.32.0 -> HFA V3 R0.23.0 Transfer failed
  6. Straces

    Hipaht 4000 - 5 minut time difference

    Hello, i have a problem on Hipath 4000, there is the time difference between Linux (correct time) and ADP (-5 minutes).. i check the Hwclock, and Date on Linux - OK i checked date in comwin - -5 minutes What is the problem? Thank you
  7. Straces

    OpenStage 40 SIP to HFA fails

    I think that HW is not supported by older firmware versions.. Check this: Hardware revisions
  8. Straces

    Optipoint 500 telephone displays

    Hello, i think that it will be simillar as for optiPoint410, there is problem with display too.. New HW - display, was introduced later: 5.1 Phone Hardware Revisions supported Starting with the Version V5 R6.1.0, you will get new hardware. With following part number: S30817-S7202-A101-27...
  9. Straces

    DERT with HFA v3 0.23.0 ?

    I used many times DERT for HFA phones in version V3 R0.16.00 and i never havd problem (at OpenStage 40 phones), maybe is better to use this version.. [thumbsup2] DERT_V1R0.0.0_HFA_3.0.16.0
  10. Straces

    35G DERT SIP

    You probably used .sci file from other firmware version, you must use files (.cfg .ini .csi) for version V3R3.33... : netboot-legacy-noudata.cfg netboot-legacy-noudata.ini netboot-legacy-noudata.sci netboot-legacy.cfg netboot-legacy.ini netboot-legacy.sci netboot-update.cfg netboot-update.ini...
  11. Straces

    DERT with HFA v3 0.23.0 ?

    Look here: http://www.tek-tips.com/viewthread.cfm?qid=1751913 [glasses]
  12. Straces

    OpenStage 40 SIP to HFA fails

    you need to update first to V2 R1.5.0, then you can safely update to V3.. just put into google: OS_40_HFA_V2_R1_5_0.img
  13. Straces

    OpenStage 40 SIP to HFA fails

    I try to change name of file but it not helps, definitely there must be something in new firmware or phone which not allow to downgrade firmware version because: SIP V3 R3.36.0 -> SIP V3 R3.32.0 working SIP V3 R3.32.0 -> SIP V3 R3.36.0 working SIP V3 R3.32.0 -> SIP V3 R3.17.0 Transfer failed...
  14. Straces

    OpenStage 40 SIP to HFA fails

    Hello, i try to upload (wit FTP) firmware from SIP (at Siemens OpenStage 40) to HFA version and it is not possible, phone writes Transfer failed. i tested it on more phones and it seems to be same, do you know some tip how to that? Why there is problem transfer from SIP to HFA, but HFA -> SIP...
  15. Straces

    Siemens DECT SL3 - Batt. mode in Service menu

    Hello, i activated Batt. mode in Service menu of the DECT Siemens Gigaset phone (SL3). Does anybody knows how can i calculate this HEX values? What exactly it showing? I find out description of metering mode only.. Thank you!
  16. Straces

    How to convert Openstage 60 HFA to SIP?

    I recommend to user FTP 1) install some FTP server on your computer (Ex: TFTP) 2) Configure it 3) Download from internet new version of HFA firmware (i recommend: OS_40_HFA_V3_R0_16_3.img) 4) Configure FTP information at phone -> Administrator -> File transfer -> Phone application 5) Download...