Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Harlock1

    MGC not registering correctly

    Thanks, works as you specified, have to add new users and use them instead of "old" admin1 / admin2 etc.
  2. Harlock1

    (OVL428) locked out

    I would not be asking the question if I did not try to do it, I can't find the reset feature for CS1000_Admin2 in the UCM, only for admin and nortel user, not for admin2 ... My question is ... where in UCM do you reset the CS users passwords for admin2
  3. Harlock1

    (OVL428) locked out

    Ok, and if that does not work?
  4. Harlock1

    (OVL428) locked out

    Hi, I had a problem under LD 117 doing a ucm registration. The MGC card tried a few times and failed, I eventually figured out what went wrong. But now the system "locked" out my admin2 user. I can rlogin to the system, then I enter cslogin or csconsole and get my CS prompt. When I do a...
  5. Harlock1

    MGC not registering correctly

    Ok, figure out the problem, I had to use a Ctrl OAM command, with admin2 user/password. Then I had to do a security domain join, but not using the TLAN, instead the ELAN ip for UCM ... strange ... But now its working ... now my next problem, I get the OVL824 password error on...
  6. Harlock1

    MGC not registering correctly

    Yip, serial you mean?
  7. Harlock1

    MGC not registering correctly

    I found part of my problem from previous post on ACOD. I am using 1120's phones, they register fine and I can call between sets. I have a CS1000E cores system, R6. MGC is 004 DSP's are 96 + 32 My TLAN is 10.10.122.120 DSP96 is 10.10.122.121 DSP32 is 10.10.122.122 I can ping the TLAN for MGC...
  8. Harlock1

    Need help with ACOD programming and FCR

    Ok thanks, I'll get a Trunk TN and Set TN tomorrow and post. I suspect something todo with NCOS, but with using FCR I should not have to worry about that right? By using LD 49 and just doing a INIT alow. I wish to get the tie up before I do any other programming. To clarify, this is a CS1000E...
  9. Harlock1

    Need help with ACOD programming and FCR

    Can someone tell me what is wrong with this config. I have two systems. system one, dn 2001, system two, dn 3001 system 1, two PRI's, slot 2 and 3 I wish to use pri in slot 3, route 3, acod 9 When I press 9 and DN of system two, the system give me a busy tone and release. My config. logi...
  10. Harlock1

    Basic routing question

    Ok, all I need is for someone to explan LD 49 and NFRL for a default table. The rest I can figure out as I go along.
  11. Harlock1

    Basic routing question

    It is all blank, seriously. I have not configured anything. (I'm an IP guy, these nodes are just to generate traffic via PRI) Well I have the nodes up, IP Phone working, and PRI's talking to each other, I can see d-channel up, msdl etc. I have nothing configured under dial plans. I want to...
  12. Harlock1

    Basic routing question

    Hi, I am trying to understand the basic FRL concept. I have two CS1000E's in a lab I have to use, they are "barely" configured. IP phones are working, and I can call inside a node. Between nodes I have have a E1 PRI TIE I've done the following: d-channel 13 30 tie lines route 3 access code 9...
  13. Harlock1

    CS1000E R6 CPPM CoRes, new UTM E1/T1 PRI card

    Thanks, I got it working, d-channel that is. Battling with a few other things now, but will do a separate post.
  14. Harlock1

    CS1000E R6 CPPM CoRes, new UTM E1/T1 PRI card

    Ok, so my superloop for the PRI will always be the virtual superloop I assigned to the MGC Card? My d-channel is "red" and under LD 60 stat dch I get MBUSY on the first timeslot only. I'll do a dump on monday if you don't mind looking at it for me. I need the following: MG1000, shelf 0 MGC in...
  15. Harlock1

    CS1000E R6 CPPM CoRes, new UTM E1/T1 PRI card

    I installed a CoRes R6 system and was given a new UTM E1/T1 card with clock controller. I can't get the d-channel up. My config is as follow: MG slot4 - - MG slot3 - UTM E1/T1 MG slot2 - - MG slot1 - CPPM CoRes MG slot0 - MGC Card (registered as 004 00) I added the PRI under LD 17 I want to...