For anyone who is interested, we fixed it.
One of our electronics guys took it apart, and found there are 4 fuses soldered on the board. 1 had blown, I don't understand how it worked at all with a blown fuse, but he said it might be something to do with a internal power amp? Anyway, with a...
Hi,
Were currently trying to move a 2250 PC Based op console.
Nothing new, same type of cabling, and basically it wont work. It worked fine where it was. Approx 600ft away.
We have verified the cable tests good, tried a few different pairs anyway.
It works perfect straight off the MDF, then...
Thanks for your help so far guys.
As a side note calls from the 81c to the 61c do not have a "H" and Vmail works fine, just 61c to 81c.
What load is the plugin commands used? im unfamiliar with that.
Thanks again.
Hi,
We have a 61c and 81c, connected via
TYPE:atvn
TRK:pri
Trouble is our voicemail system is off the 81c and calls coming from the 61c have a "H" in from of the caller id so the voicemail doesnt know what to do with it.
Ive changed CLS on a 500 set on the 61c to CLBD and it works fine as...
Hi,
We have several locations (of which someone could be in anyone of them) and I wanted to make every phone ring by dialling one number. I would have used a ring generator but like I said were limited on pairs to some locations.
Thanks for your help.
Sorry, my apologies, should have mentioned they are 500 sets.
Im trying to put external ringers in, which I currently have doubled off each POT TN.
Thanks
Hi,
Ive been reading about the group call feature on here. I have one set up on our 81c with 17 members (I Think) I assumed id be able to do the same on our 11c but alas, no. It says the max is 6. IS there anyway to change this? Were kinda short of CO pairs to some locations.
Thanks!
Hi, Anyone know a way of using the DIG feature to page multiple sets at once? I can only figure it to go set to set, but would like to broadcast voice over about 20 sets.
Any ideas? Thanks
Thanks for all your help guys.
I checked all wiring and it was good. IT ended up giving me a BSD090 error and suggested the CMAJ command.
This appeared to do nothing but next morning I went back through the logs and after the midnight routine the problem went!
Thanks again.
Thanks for your reply,
I looked at the XSM I got -
PWR000 XSMC 00 0 0
PWR013 XSMC 02 0 0
PWR013 XSMC 03 0 0
PWR013 XSMC 04 0 0
PWR013 XSMC 01 0 0
I checked the error codes and I guess 00 is good and the rest bad?
I looked at the history file too and there are allot (100's) of PRI254 errors...
Hi,
Our 81C keeps running through an INterloop test? Not sure why, we've had no copmplaints, but its constantly cycling through tests and switching cores. Both cores look healthy.
Any ideas??
Thanks!
OKay just done a DTR test. The first card fails and gets dsbl. THe other 4 all pass! SO I guess thats my problem :(
Ill replace it first thing tomorrow. THanks for all your help!
Hi, thanks for your help.
Ive stat'd all DTRS and all 5 cards are idle and also stat'd the 4 TDS loops - all up and showing 0 DSBL.
Any other ideas? Thanks again!
Were having a problem in that we cant break dial tone on allot of POTs. Everything else is fine. The POTs are on different loops / shelfs. The switch health count is correct. Any ideas? Thanks
Yes we are, but having read that article (Quite interesting!!) We are not using the trunks for what Autovon was designed for. So am not sure why they are set that way.
Could the fact they are Autovons be my problem?
Glad to hear its a common thing we are trying.
I know we have a support contract so I guess from what your saying the average switch tech (me) probably shouldnt attempt this? is it difficult to configure? and I should actually utilize what we pay for??
Just looking at the drawings (and I know...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.