The SLT device is connected directly to the SLT port on the mother board. We tried with the buttinski same result. Could it be the RGU inbuilt on the mother board?
Hi everyone,
I replaced an aria 16 with an Aria 24IP. It works with with 3 extensions, 2 digital and one SLT, 10,11 and 12. It got initialised to factory setting and reprogrammed. My problem is with the SLT. I can ring the other ext 10 and 11 and it shows that it is coming from ext 12 but I...
I have installed a additional circuit board 3lines 8 extensions(number 3) on a existing ZEN Topaz that already works with 6 lines and 16 extns. The extensions are working fine but I cannot get the exchange lines to work. There was 2 exchange port left on the second card which I'm now using but...
Hi ,
sorry for the delay, I went to the customer premise only today.
• I have tested 601 for ring and I'm getting a busy tone
• 006 does not accept the change from 101 to 601
still no solution
basic stuff
• The system reinitialised - done
• DIL 1-1 in 450 - destination 601 - done
• ICD extn grouping in 620 - done
Result no change, still only extn 101 ringing while the other extention have a red light.
I'm pulling my hair out
thanks for your help
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.