I have a 1000cs 7.5 using 3904 with multiple add-ons. A call comes into key 54 it is answered next call goes to key 55 it is showing the CLID of key 54. I have tried to duplicate on test phone without add-ons I can't. Also these phones are on Call Parrtot Talk line cards.
Well I am going to assume ( we know what happens when we do that ) that all is good . I have gotten no trouble calls associated with any of these loops. Thanks for all your help and suggestions.
I have all three at this site . With that said XMI001 17 XMLC with no other info. How would one determine where that card is. There is no longer card slot 17 anywhere .
Morning Folks, Have a puzzler ... I have a 1000E 7.5 I got an XMI001 17 . Looking at this it talks about the card in the expansion cabinet. I have no expansion cabinets as I knew them. Everything is either MGS or MGC . Any Ideas
GHTROUT , already there , again everyone out there can call except Comcast customers. I am hesitate to make a change in the PBX for that reason. Do not want to break 2 to fix none.
Thanks for the reply , D-channel option is not there . There are 10 + T-1's involved way to much traffic. I turn it on and it will flood my TTY port . I was hoping someone worked with comcast and knew what on there end was causing this.
Morning, I have a CS1000 7.5 . We have a T-1 built and attached to a server with DID pointed to it . This is for dictation purposes. All works fine unless you are calling from a Comcast owned phone number. I this case you get reorder . We had this issue a few years back and it was resolved by...
I passed on Avaya's recommendation to customer they bought in. The bigger hard drive is the difference as far as I know. Also when patching it certainly seems to go faster with the CPDC. If I remember correctly Avaya said the CP-PM's were coming to EOD. Thanks agian for the reply's. You all have...
Thanks for the reply. It is a member server one of two in this PBX. We are replacing all the CP-PM with CP-DC, it was recommended by Avaya Support. I ready have software loaded and patched. I did get a couple different opions on how to go about replacing it. Just looking to see if there was...
Good afternoon all, I need to replace a 7.5 CP-PM Sig Server with a CP-DC Sig Server. I have been searching for a process for this and have come up empty. Would any of you folks now of a document out there ?
Morning, I have two SMG's both are kicking out this error SPRT315( Not able to recover heartbeat link with MGC Cabinet 1/17/18/19/20. I am getting this on both SMG's. not on the "E". You only see it when logged into the SMG's. Any ideas ?
I am not buying it either but I have to go with the recommendations. This all has to do with static. With LD-30 in midnights when the clock switches from "0" to "1" we get staic system wide. I have replaced both Clocks and numerous FIJI cards. And this does not happen all the time.Thanks again
Looking for some guidence , I have a cs1000k 7.5 with static issues . Recommended that we replace the CLK cable (1) . Can this be done with out effecting service ? Thanks